Enmet ISA-44-2OD Manual do Utilizador Página 14

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 13
ENMET Corporation ISA-44-2-OD
10
Relay Hook-up
See Figure 8 for an example of how to use the relay contacts.
Table 5: Relay Function
Relay
Channel function
K1 1 High Alarm
K2 1 Low Alarm
K3 2 Oxygen
K4 3 High Alarm
K5 3 Low Alarm
CAUTION: Actual wiring will not exit the enclosure at the nearest point. The bottom of the enclosure is the best
entrance/exit surface. You must punch holes and use NEMA-4X watertight fittings.
Figure 8: Suggested Relay Hook-Up Configuration
Fan
Relay
110V
AC
Low
110V
AC
Low
110V
AC
High
110V
AC
High
External Lamp
(Amber)
External Lamp
(Red)
External
Horn
Install a separate
switch to silence
an auxiliary alarm
K1
K2
K3K3
K4
K5
TB1
TB2
TB3
TB6
TB4
TB5
Vista de página 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 31 32

Comentários a estes Manuais

Sem comentários